SHAFT PREMATURE FAILURE ANALYSIS IN ELECTRICAL SUBMERSIBLE PUMP SYSTEM: A CASE STUDY FROM MUARA ENIM, SOUTH SUMATERA, INDONESIA

Authors

  • Diah Kusuma Pratiwi
  • Yudianto Yudianto Department of Mechanical Engineering, Faculty of Engineering, Unviersitas Sriwijaya, Ogan Ilir – 30662, South Sumatera, Indonesia
  • Agung Mataram Department of Mechanical Engineering, Faculty of Engineering, Unviersitas Sriwijaya, Ogan Ilir – 30662, South Sumatera, Indonesia
  • Akbar Teguh Prakoso Department of Mechanical Engineering, Faculty of Engineering, Unviersitas Sriwijaya, Ogan Ilir – 30662, South Sumatera, Indonesia

DOI:

https://doi.org/10.36706/jmse.v9i1.71

Keywords:

Failure, Submersible Pump System, Shaft

Abstract

The shaft is a critical component in ESP. In many cases, dismantle analyses cannot identify a definitive root cause for shaft failure. Several hypotheses have been studied to explain shaft failure. This paper will review typical shaft failure modes; more specifically, the power source and the consequence of shaft failure will be discussed. An analysis of the premature failure of the shaft used in an electrical submersible pump (ESP) for lifting oil has been carried out. During shaft failure root-cause analysis, mechanical components have been the primary focus. Chemical analysis, microstructure characterization, fractography, and hardness test were used. In addition, the shaft running stress and the possibility condition (the condition of the possible broken shaft has been approached analysis using finite element analysis). It was concluded that the material defects were the prime cause of the shafts' premature failure.

Downloads

Download data is not yet available.

References

Joel Romero O and Hupp A 2014 Subsea Electrical Submersible Pump Significance in Petroleum Offshore Production J. Energy Resour. Technol.

Durham R A and Brinner T R 2015 Oilfield Electric Power Distribution IEEE Trans. Ind. Appl.

Thorsen O V and Dalva M 2001 Combined electrical and mechanical model of electric submersible pumps IEEE Trans. Ind. Appl.

Vandermeulen A H, Natali T J, Dionise T J, Paradiso G and Ameele K 2019 Exploring New and Conventional Starting Methods of Large Medium-Voltage Induction Motors on Limited kVA Sources IEEE Transactions on Industry Applications

Ledoux K, Visser P W, Hulin J D and Nguyen H 2015 Starting large synchronous motors in weak power systems IEEE Trans. Ind. Appl.

Pragale R and Shipp D D 2017 Investigation of Premature ESP Failures and Oil Field Harmonic Analysis IEEE Trans. Ind. Appl.

Farbis M, Hoevenaars A H and Greenwald J L 2016 Oil field retrofit of ESPs to meet harmonic compliance IEEE Trans. Ind. Appl.

El-Mahayni R, Al-Qahtani K and Al-Gheeth A H 2016 Large Synchronous Motor Failure Investigation: Measurements, Analysis, and Lessons Learned IEEE Trans. Ind. Appl.

McVeigh C, Vernerey F, Liu W K, Moran B and Olson G 2007 An interactive micro-void shear localization mechanism in high strength steels J. Mech. Phys. Solids

Sunandrio H and . S 2014 Analisis Kegagalan Shaft Pompa Submersible Pada Unit Pengeboran Minyak Bumi = Failure Analysis Of Pump Shaft Submersible On Oil Drilling Unit Mater. Kompon. dan Konstr.

ASM International 2004 ASM Handbook Vol 9: Metallography and Microsctructures ASM Int.

Devendranath Ramkumar K, Naren S V, Karthik Paga V R, Tiwari A and Arivazhagan N 2016 Development of pulsed current gas tungsten arc welding technique for dissimilar joints of marine grade alloys J. Manuf. Process.

Marenych O and Kostryzhev A 2020 Strengthening mechanisms in nickel-copper alloys: A review Metals (Basel).

ASTM 2015 B865-04 - Standard Specification for Precipitation Hardening Nickel-Copper-Aluminum Alloy ( UNS N05500 ) Bar , Rod , Wire , Forgings , and Forging Stock Astm

ASTM Internaional 2012 ASTM E140-12b. Standard Hardness Conversion Tables for Metals Relationship Among Brinell Hardness, Vickers Hardness, Rockwell Hardness, Superficial Hardness, Knoop Hardness, Scleroscope Hardness, and Leeb Hardness Am. Soc. Test. Mater.

Aminipour N and Derakhshandeh-Haghighi R 2019 The Effect of Weld Metal Composition on Microstructural and Mechanical Properties of Dissimilar Welds Between Monel 400 and Inconel 600 J. Mater. Eng. Perform.

Special Metals Corporation 2000 High-Performance Alloys for Resistance to Aqueous Corrosion

G. Budynas R and Nisbett J K 2017 Shigley’s Mechanical Engineering Design, 9th Edition-McGraw-Hill